Global motion and local correspondence reliability in respiratory 4D imaging under simulated failure conditions

Lin, Weixiang, Xiao, Chengjian, Lai, Zhen, Xiao, Liangjie, Lu, Shipei, Wang, Yuliu, Lin, Xiaosheng, Fang, Jianlan, Fang, Yongwen, Chi, Feng
Springer Nature · 2026-11-23 · DOI 10.1186/s12885-026-17304-4

Abstract

Background Reliable phase-to-phase correspondence in respiratory four-dimensional computed tomography (4DCT) is important for motion assessment and image-guided radiotherapy in lung cancer. However, plausible global motion estimates may coexist with weak or ambiguous local correspondence. We investigated whether pair-level respiratory motion and grid-specific local correspondence evidence provide distinct information for discriminating truth-defined correspondence failures in a controlled synthetic benchmark. Methods A newly constructed controlled synthetic benchmark used one automatically selected central axial plane from each of 44 traceable source images belonging to 20 patients, including 4DCT-origin and 4D-CBCT acquisitions. No volumetric correspondence assessment was performed. Six predefined challenge mechanisms generated 528 synthetic challenges and 13,200 local grid positions. Each challenge received one shared displacement estimate, and correspondence error was evaluated against known synthetic displacement at 25 grid positions. Of 12,980 evaluable positions, 3,445 were classified as failures using a displacement-error threshold of greater than 2 pixels. Global-descriptor, local-evidence and combined models were evaluated using leave-one-patient-out validation. Separately, published CREATIS anatomical landmarks were evaluated in four image-complete subjects. Results In the new synthetic benchmark, the global-descriptor model (M0), local-evidence model (M1) and combined model (M2) achieved AUROCs of 0.452, 0.932 and 0.930, respectively, with average precision values of 0.295, 0.870 and 0.877. Adding global descriptors to local evidence did not improve AUROC (difference, − 0.002; 95% patient-cluster bootstrap CI, − 0.008 to 0.001). Three of the six challenge mechanisms produced no evaluable failure events. In a post hoc analysis restricted to the three mechanisms containing both outcome classes, the corresponding AUROCs were 0.658, 0.863 and 0.869. Four subjects provided 413 evaluable landmark pairs; an exploratory 28-point near-coplanar extension yielded an AUROC of 0.775 and specificity of 0.500, without direct validation of the original central-plane design. Conclusions In the newly constructed synthetic benchmark, local correspondence evidence provided better discrimination of truth-defined displacement errors than the restricted global-descriptor model. However, performance varied across challenge mechanisms, and three mechanisms produced no evaluable failures. These findings support further investigation of local evidence as a potential correspondence-audit tool, but they do not establish its effectiveness for detecting clinically observed respiratory registration failures.

Read at publisher →