Veterinary Surgery General Veterinary

Comparative biomechanical study of a novel variable diameter circular external fixation device ( <scp>VDCF</scp> ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens

Rohit Kumar, T. Sai Kumar, K. S. Kamalesh Kumar, Abhishek C. Saxena, Aman Kumar Tiwari, Abhijit Pawde, Amarpal, Rekha Pathak, O. R. Vinodh Kumar
Wiley · 2026-11-16 · DOI 10.1111/vsu.70177

Abstract

Abstract Objective To compare the biomechanical performance of a novel variable diameter circular external fixation device (VDCF) with a conventional circular external fixator (CEF) using a standardized osteotomized buffalo tibia model under axial compression and torsional loading. Study design Experimental in vitro biomechanical comparative study. Sample population A total of 36 adult bovine tibiae obtained postmortem from buffaloes. Methods The tibiae were randomly allocated into three groups ( n = 12 each): VDCF, CEF, and intact bone. A standardized mid‐diaphyseal transverse osteotomy with a 20 mm gap was created to simulate an unstable fracture model. Constructs were subjected to axial compression and torsional testing to failure using displacement‐controlled protocols. Key biomechanical parameters evaluated included failure load, axial stiffness, and maximum torque derived from load–deformation curves. Statistical analysis was performed using one‐way ANOVA followed by Tukey's HSD test. Results Intact tibiae demonstrated significantly greater failure load and axial stiffness than both fixation constructs ( p < .05). No significant differences were detected between VDCF and CEF in failure load or axial stiffness ( p > .05). During torsional testing, maximum torque did not differ significantly between constructs ( p > .05); however, VDCF exhibited significantly greater torsional stiffness than CEF ( p < .05). Failure modes were primarily characterized by plastic deformation and wire bending in both constructs, while fixation‐bolt loosening was observed only in the CEF group. Conclusion The VDCF showed no significant differences compared with conventional circular external fixation in failure load, axial stiffness, maximum torque, and torsional strength, while exhibiting significantly greater torsional stiffness under the experimental conditions. Clinical significance/impact The VDCF represents a potential alternative fixation configuration with practical advantages in construct adaptability and cost for fracture stabilization in large animals.

Read at publisher →