ABSTRACT Aim To evaluate and compare the positional accuracy of complete arch intraoral digital implant scans obtained using a conventional scan body protocol and a customized metallic ring‐based calibrated framework. Materials and Methods A completely edentulous arch restored with six implants was scanned using two complete arch intraoral digital impression protocols: a conventional scan body protocol (SB) and a metallic ring‐based calibrated framework (CF). Twenty scans were obtained per group using the same intraoral scanner. A coordinate measuring machine (CMM) dataset served as the reference standard. All STL files were imported into dental CAD software to design a standardized virtual implant‐supported bar, which was subsequently analyzed using reverse engineering software. Linear inter‐implant distances and angular deviations were calculated. Trueness was defined as the absolute deviation from the CMM reference, and precision as the variability among repeated scans. Between‐group comparisons were performed using independent t ‐tests with Welch correction and Holm adjustment ( α = 0.05). Results The mean linear deviation was 0.034 (0.004) mm for CF and 0.124 (0.019) mm for SB ( p < 0.01). The mean angular deviation was 0.31 (0.05) degrees for CF and 0.55 (0.10) degrees for SB ( p < 0.01). Conclusions The calibrated splinting protocol showed greater trueness and lower variability compared with the conventional scan body approach.
Miguel Gómez‐Polo, Solange Vasquez‐Ramos, Marta Revilla‐León, Rocío Cascos. Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study. // Clinical Oral Implants Research. – 2026. – DOI: 10.1111/clr.70192. – URL: https://onlinelibrary.wiley.com/doi/10.1111/clr.70192?af=R
Miguel Gómez‐Polo, Solange Vasquez‐Ramos, Marta Revilla‐León, & Rocío Cascos (2026). Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70192
Miguel Gómez‐Polo, et al. “Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study.” Clinical Oral Implants Research, 2026. doi:10.1111/clr.70192.
@article{GmezPolo2026,
title = {Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring‐Based Calibrated Framework: An In Vivo Study},
author = {Gómez‐Polo, Miguel and Vasquez‐Ramos, Solange and Revilla‐León, Marta and Cascos, Rocío},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70192},
url = {https://onlinelibrary.wiley.com/doi/10.1111/clr.70192?af=R}
}
ABSTRACT Objectives To compare the passive fit, accuracy discrepancy, patient‐reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete‐arch implant‐supported...
ABSTRACT Background/Aim This study investigated dentists' self‐reported treatment confidence and their interest in AI‐supported assistance in the field of dental traumatology among dentists in Lower Saxony, Germany. Material and Methods...
ABSTRACT Background The long‐term success of replanting an avulsed tooth depends fundamentally on preserving the viability of the periodontal ligament fibroblasts and associated mesenchymal stem cells adhering to the root surface. When...
ABSTRACT Background Complex dentoalveolar fractures may result in irreversible tooth loss, but the clinical factors associated with overall tooth loss and their prognostic relevance at initial assessment remain insufficiently defined....