Established uncertainty evaluation method associated with weighing for serum glucose quantification based on ID-LC-MS/MS
Аннотация
In order to ensure comparability of uncertainties for serum glucose quantified by ID-LC-MS/MS, a comprehensive uncertainty evaluation method was established, especially associated with weighing. A set of class E 2 weights were weighed under repeatability conditions, then the indication error, standard deviation and uncertainty of each weight were combined to the uncertainty of repeatability ($${u}_{\text{r}\text{e}\text{p}.\text{r}\text{e}\text{l}}$$). The relationship between the indications and certified mass of all weights was established by linear least square fitting, then the uncertainties of slope and temperature coefficient were combined to the uncertainty of linearity ($${u}_{\text{L}.\text{r}\text{e}\text{l}}$$). Test load at least Max/3 was used to evaluate the uncertainty of eccentricity ($${u}_{\text{e}\text{c}\text{c}\text{i}.\text{r}\text{e}\text{l}}$$). Uncertainties of the densities for weights, samples and air were combined to the uncertainty of buoyancy correction factor($${u}_{{\text{B}}_{\text{u}}.\text{r}\text{e}\text{l}}$$). The contribution of $${u}_{\text{r}\text{e}\text{p}.\text{r}\text{e}\text{l}}$$, $${u}_{\text{L}.\text{r}\text{e}\text{l}}$$, $${u}_{\text{e}\text{c}\text{c}\text{i}.\text{r}\text{e}\text{l}}$$ and $${u}_{{\text{B}}_{u},\text{r}\text{e}\text{l}}$$ to the combined uncertainty of weighing ($${u}_{c\left({\text{m}}_{\text{s}}\right).\text{r}\text{e}\text{l}}$$) were then calculated. At low weighing mass (≤112.7 mg), $${u}_{\text{r}\text{e}\text{p}.\text{r}\text{e}\text{l}}$$ is the maximum uncertainty contribution, whereas $${u}_{{\text{B}}_{u}.\text{r}\text{e}\text{l}}$$ becomes the major contribution for higher mass (>20 g). When weighing object is 1.9497 g, both $${u}_{\text{r}\text{e}\text{p}.\text{r}\text{e}\text{l}}$$ and $${u}_{{\text{B}}_{u}.\text{r}\text{e}\text{l}}$$ are significant uncertainty contributors. Other contributions which are less than 10% of the maximum contribution can be ignored. For the two external quality assessment (EQA) samples with different concentrations (RELA-A and RELA-B), $${u}_{c\left({\text{m}}_{\text{s}}\right).\text{r}\text{e}\text{l}}$$ were 0.0652 and 0.0515%, respectively. When evaluation $${u}_{c\left({\text{m}}_{\text{s}}\right).\text{r}\text{e}\text{l}}$$ based on ID-LC-MS/MS, only $${u}_{\text{r}\text{e}\text{p}.\text{r}\text{e}\text{l}}$$ and/or $${u}_{{\text{B}}_{u}.\text{r}\text{e}\text{l}}$$ should be taken into account.