High Energy Chemistry
Издатель: Springer Nature · 19 статей
-
Scoreability burden in multi-round AQUACHECK water-chemistry proficiency testing: an analyte–matrix–method assessment-burden atlas from 18 PT rounds
Proficiency testing (PT) in water chemistry is commonly interpreted through z-score performance classifications, but multi-round schemes also contain assessment constraints that modify or prevent ordinary direct scoring. This...
-
Collaborative trial in sampling for validation of measurement procedures that include sampling
A case study is used to explain how measurements taken from a collaborative trial in sampling (CTS) can be used to simultaneously validate an entire measurement procedure, including both the sampling and the analytical steps. Nine...
-
Homogeneity and stability evaluation of EQA serum samples for Chikungunya IgM ELISA
Chikungunya, a mosquito-borne viral disease caused by Chikungunya virus (CHIKV), infects humans through the bite of Aedes sp. mosquitoes, causing high fever. Diagnosis includes the detection of IgM antibodies against CHIKV by ELISA....
-
Methods for evaluating the fractional composition of particulate matter from the perspective of determining measurement uncertainties
The fractional composition of particulate matter represents their fundamental property, which influences their use in specific applications. Therefore, it can be a subject of testing in accredited laboratories. It is often determined by...
-
Multi-parameter correlation anomaly detection for petroleum product compliance testing
Routine petroleum product testing evaluates each parameter independently against its specification limit under a single-parameter compliance paradigm that implicitly assumes parameter independence. This study challenges that assumption,...
-
Characterization of blank matrix reference materials by non-target LC-HRMS analysis
Blank matrix reference materials (RMs) are representative of a typical test matrix, but contain levels of target measurands below method limits of detection (LOD). In the absence of target measurands, conventional approaches used in the...
-
Established uncertainty evaluation method associated with weighing for serum glucose quantification based on ID-LC-MS/MS
In order to ensure comparability of uncertainties for serum glucose quantified by ID-LC-MS/MS, a comprehensive uncertainty evaluation method was established, especially associated with weighing. A set of class E 2 weights were weighed...
-
Audit-traceable harmonization of legacy calibration certificates for ISO/IEC 17025 laboratory quality assurance
Legacy calibration certificates can support longitudinal equipment surveillance only after unit, structure, identity and provenance differences have been controlled. This study developed an audit-traceable row-level harmonization...
-
ISO 7218:2024 in official control food microbiology laboratories: key revisions, quality implications, operational challenges, implementation considerations, and opportunities for harmonization
The updated version of ISO 7218:2024, titled “Microbiology of the food chain—General requirements and guidance for microbiological examinations”, serves as a significant horizontal standard that underpins microbiological testing...
-
Long-term performance assessment of neutron activation analysis at the RA-3 reactor based on international proficiency testing
Neutron activation analysis (NAA) is a primary analytical technique for the multi-element determination of major, minor, and trace elements in diverse matrices, providing high accuracy and minimal sample preparation. At the Nuclear...
-
An asymmetric sample design for source-oriented diagnostic information in proficiency testing
In proficiency testing (PT), a result outside the satisfactory range may indicate a performance concern without identifying the likely source of the deviation. This study examined whether prior differentiation of sample roles could...
-
Quantifying in-use storage-time uncertainty for HPLC working standard solutions: a comparative study of three assessment methods
In this study, we systematically evaluated the contribution of storage time to measurement uncertainty for six pharmacopoeial certified reference materials (CRMs) over 180 days under in-use conditions. The experimental...
-
Practical approach to managing risks in a testing laboratory—ISO/IEC 17025:2017 perspective
It is important for a testing laboratory to proactively identify risks so as to prevent or reduce the occurrence of failures in the laboratory activities and to ascertain the validity and reliability of test results. The ISO/IEC...
-
A probabilistic classification framework for laboratory performance evaluation in mycotoxin proficiency testing: integrating z -scores, ζ-scores and measurement uncertainty
Proficiency testing (PT) programmes in mycotoxin analysis predominantly rely on the z -score for participant performance evaluation, which does not incorporate the laboratory's reported measurement uncertainty. In this study, 2,538...
-
Artificial intelligence for testing and calibration laboratory systems: a structured systematic review and ISO/IEC 17025-oriented governance framework
Artificial intelligence (AI) is increasingly being explored for laboratory testing, calibration, data management, and decision support. For laboratories operating within ISO/IEC 17025-oriented quality systems, however, AI adoption...
-
The digital reference material document (DRMD): a new member of the DCC-based family of quality documents
The digital reference material document (DRMD) extends the digital calibration certificate (DCC)-based family of digital quality documents by offering a flexible, machine-readable format for reference material documents in line with ISO...
-
Single-point assessment and long-term evaluation of quantitative proficiency testing results in a food microbiology laboratory
Participation in proficiency testing is one of the important measures to monitor the performance of a laboratory. It serves as an external measure of a laboratory’s ability to produce accurate and reliable results and verifies the...
-
Development and application of a layered risk management framework for a clinical biochemistry laboratory in accordance with ISO 15189:2022
Laboratory errors across the total testing process pose significant risks to patient safety, with downstream implications for diagnostic accuracy, particularly in high-workload clinical biochemistry laboratories. The revised...
-
A longitudinal evaluation of clinical microbiology laboratory proficiency in a large-scale urban eqa program: insights into diagnostic accuracy and antimicrobial resistance surveillance (2022–2025)
External quality assessment (EQA) is an essential component of clinical microbiology, ensuring diagnostic reliability and underpinning antimicrobial resistance (AMR) surveillance. However, longitudinal data evaluating inter-tier...